Category:

PT Series


COMPLETE SYSTEM FOR PIPETTE CHECKING
Pipettes are widely used instruments in laboratories and their proper maintenance is essential to ensure correct and reliable results. Each laboratory should establish a regular verification program, in order to carry out their preventive maintenance or (re) calibration, if necessary.
  
This series of balances is designed for the verification of piston pipettes using the gravimetric method. The embedded “Pipette Check” software allows you to test the correct operation of a pipette by selecting a verification method. At the end, a detailed report is generated with the overall test result (compliant or not-compliant pipette) and the relative partial values.
  
The -PT models include the evaporation trap that consists of a special weighing container designed to considerably reduce the evaporation of the liquid which occurs naturally during the pipette test procedure. If not well taken into consideration, this effect will negatively affects the tests by increasing the measurement error leading to an incorrect final result, especially in the case of small volumes. The evaporation trap creates a saturated area of water vapor above the test tube containing the liquid coming from the pipette, thus the evaporation of the latter is minimal during the procedure and reliable results can be obtained.
  

Touchscreen DisplayTouchscreen Display:
technology, user friendly, easy to use and intuitive.
DatabaseDatabase:
Internal database to store data
Glp SetupGlp Setup:
Allows to store identification data of balance, project and user. Date and Time.


Share it:
  • Overview
  • Models
  • Download
  • Contact Us
  • Technical Features

Overview

  • 5 inch color touch-screen display (800×480)
  • Automatic internal calibration
  • Draftshield with 3 sliding doors
  • RS232 serial output
  • Selectable measuring units
  • On-board Software functions: Pipette Check, piece counting, Check weighing, Percentage weighing, Statistics, Animal weighing, Peak hold, Density determination, Recipe, Textile
  • GLP protocol
  • Internal Database
  • Multi language (ITA-ENG-ESP-POR-GER
  • Multi-user with password protection
  • USB port to import/export data of database

Verifiable pipette types:

  • Fixed Volume / Variable Volume
  • Air displacement / Positive displacement (reusable) / Positive displacement (disposable)

Verification methods:

  • ISO8665
  • 4x (100% 10%): 4 samples at 100% and 10% of the nominal volume
  • 4x (100%): 4 samples at 100% of the nominal volume
  • Custom: number of samples and percentage of the volume of your choice

 

Customized control methods can also be defined: the volumes to be checked and the number of samples can be entirely defined by the user.

It is possible to identify whether a pipette needs maintenance or (re)calibration by assessing its performance according to the specifications given by the ISO8665 directive

  

Database:

For frequent or many pipette checks at a time, pipette informations (model, serial number, pipette type, tip, number of channels, nominal value, …) can be stored in the balance’s internal database for easy recall and greater speed of the control procedure.

Models

Which balance’s model to choose:

The balance must be chosen based on the volume of the pipette to be checked. Smaller volumes will need higher resolution balances. Within the current family of balances for pipette checking it is possible to check the following volumes, in accordance with the ISO 8665 standard:

However, the balances of this series can always be used for normal laboratory weighing operations; in the case of -PT models, the evaporation trap is easily removable.

Download

FLYER

Flyer

Contact Us

    Your Name (required)

    Your Email (required)

    Company Name (required)

    Country/City (required)

    Your Message

    Technical Features